2 resultados para in-flight tests

em AMS Tesi di Laurea - Alm@DL - Università di Bologna


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The lateral characteristics of tires in terms of lateral forces as a function of sideslip angle is a focal point in the prediction of ground loads and ground handling aircraft behavior. However, tests to validate such coefficients are not mandatory to obtain Aircraft Type Certification and so they are not available for ATR tires. Anyway, some analytical values are implemented in ATR calculation codes (Flight Qualities in-house numerical code and Loads in-house numerical code). Hence, the goal of my work is to further investigate and validate lateral tires characteristics by means of: exploitation and re-parameterization of existing test on NLG tires, implementation of easy-handle model based on DFDR parameters to compute sideslip angles, application of this model to compute lateral loads on existing flight tests and incident cases, analysis of results. The last part of this work is dedicated to the preliminary study of a methodology to perform a test to retrieve lateral tire loads during ground turning with minimum requirements in terms of aircraft test instrumentation. This represents the basis for future works.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The revision hip arthroplasty is a surgical procedure, consisting in the reconstruction of the hip joint through the replacement of the damaged hip prosthesis. Several factors may give raise to the failure of the artificial device: aseptic loosening, infection and dislocation represent the principal causes of failure worldwide. The main effect is the raise of bone defects in the region closest to the prosthesis that weaken the bone structure for the biological fixation of the new artificial hip. For this reason bone reconstruction is necessary before the surgical revision operation. This work is born by the necessity to test the effects of bone reconstruction due to particular bone defects in the acetabulum, after the hip prosthesis revision. In order to perform biomechanical in vitro tests on hip prosthesis implanted in human pelvis or hemipelvis a practical definition of a reference frame for these kind of bone specimens is required. The aim of the current study is to create a repeatable protocol to align hemipelvic samples in the testing machine, that relies on a reference system based on anatomical landmarks on the human pelvis. In chapter 1 a general overview of the human pelvic bone is presented: anatomy, bone structure, loads and the principal devices for hip joint replacement. The purpose of chapters 2 is to identify the most common causes of the revision hip arthroplasty, analysing data from the most reliable orthopaedic registries in the world. Chapter 3 presents an overview of the most used classifications for acetabular bone defects and fractures and the most common techniques for acetabular and bone reconstruction. After a critical review of the scientific literature about reference frames for human pelvis, in chapter 4, the definition of a new reference frame is proposed. Based on this reference frame, the alignment protocol for the human hemipelvis is presented as well as the statistical analysis that confirm the good repeatability of the method.